title: AS 2550.10 EWP Major Inspection Update — What Fleet Operators Need to Do
description: Stay compliant with AS 2550.10 EWP major inspection updates. Ensure your fleet meets new requirements for 5 and 10-year inspections before deadlines.
image: https://deg.nz/hubfs/ewp-photo2%20(1).jpg
---

[Skip to content](https://deg.nz/insights/as-2550.10-ewp-major-inspection-update-what-fleet-operators-need-to-do#main-content)

[![DEG-primary logo-white-RGB - Copy](https://deg.nz/hs-fs/hubfs/Website%20images/DEG-primary%20logo-white-RGB%20-%20Copy.png?width=125&height=55&name=DEG-primary%20logo-white-RGB%20-%20Copy.png "DEG-primary logo-white-RGB - Copy")](https://deg.nz)

 Services

Consulting Engineering

Survey & Inspection

Calibration & Compliance

 Industries

Energy & Utilities

Manufacturing & Processing

Fabrication & Construction

Marine & Ports

Civil Infrastructure

 Safety & Quality

Approach (Scale)

Accreditations & Quality

Safety & Compliance

 Resources

Insights

Compliance Updates

Technical Guidance

Case Studies

 About

About DEG

Our History

Leadership Team

Careers

Contact Us

 Services

[Consulting Engineering](https://deg.nz/consulting-engineering) [Survey & Inspection](https://deg.nz/survey-inspection) [Calibration & Compliance](https://deg.nz/calibration-compliance)

 Industries

[Energy & Utilities](https://deg.nz/energy-utilities) [Manufacturing & Processing](https://deg.nz/manufacturing-processing) [Fabrication & Construction](https://deg.nz/fabrication-construction) [Marine & Ports](https://deg.nz/marine-ports) [Civil Infrastructure](https://deg.nz/civil-infrastructure)

 Safety & Quality

[Approach (Scale)](https://deg.nz/our-approach) [Accreditations & Quality](https://deg.nz/accreditations-quality) [Safety & Compliance](https://deg.nz/safety-compliance)

 Resources

[Insights](https://deg.nz/insights) [Compliance Updates](https://deg.nz/compliance-updates) [Technical Guidance](https://deg.nz/technical-guidance) [Case Studies](https://deg.nz/case-studies)

 About

[About DEG](https://deg.nz/about) [Our History](https://deg.nz/our-history) [Leadership Team](https://deg.nz/leadership-team) [Careers](https://deg.nz/careers)

[Contact Us](https://deg.nz/contact-us)

![](https://deg.nz/hs-fs/hubfs/ewp-photo2%20(1).jpg?width=1000&height=667&name=ewp-photo2%20(1).jpg)

#wedoallthingssafely #wedothingsright

# AS 2550.10 EWP Major Inspection Update — What Fleet Operators Need to Do

![DEG](https://deg.nz/hs-fs/hubfs/Red%20D-1.png?width=48&height=48&name=Red%20D-1.png)

 DEG

April 28, 2026

If you operate an elevating work platform (EWP) fleet, the current edition of AS 2550.10 sets the requirements for your 5 and 10-year major inspections. There have been updates to the standard that affect what is required before your next major — and with many fleets having machines approaching that milestone, now is the time to check your records.

AS 2550.10 covers the in-service inspection and maintenance of EWPs, including boom-type and scissor-type platforms. The major inspection (required at 5 years and again at 10 years from commissioning) goes well beyond the 6-monthly in-service check. It includes a full structural assessment, non-destructive testing of critical components, function testing, and — for insulated booms used in live-line electrical work — high voltage testing of the boom insulation and bucket liner.

Key points from the current edition:  
\- The major must be carried out or supervised by a competent person with documented qualifications for the specific machine type.  
\- NDT requirements for structural components are more clearly defined, including acceptance criteria for welds and boom sections.  
\- For HV-rated EWPs, acoustic emission testing to AS 4748 is required on fibreglass boom sections as part of the major.  
\- Records of the major must be retained and available for inspection — a gap in documentation is treated the same as a gap in compliance.

DEG carries out EWP major inspections nationally, including HV boom and bucket liner testing to ANSI/SIA A92.2 and acoustic emission testing to AS 4748. We issue BPG-compliant certificates and maintain records through our compliance management system.

If your machines are approaching a 5 or 10-year major, get it scheduled before the window closes.

Reference links:  
Standards New Zealand — AS 2550.10:  
https://www.standards.govt.nz/shop/asnzs-255010-2006/

WorkSafe — EWPs overview:  
https://www.worksafe.govt.nz/topic-and-industry/elevated-work-platforms/

## Share this post

<https://www.facebook.com/sharer/sharer.php?u=https%3A%2F%2Fdeg.nz%2Finsights%2Fas-2550.10-ewp-major-inspection-update-what-fleet-operators-need-to-do><https://twitter.com/intent/tweet?url=https%3A%2F%2Fdeg.nz%2Finsights%2Fas-2550.10-ewp-major-inspection-update-what-fleet-operators-need-to-do><https://www.linkedin.com/shareArticle?mini=true&url=https%3A%2F%2Fdeg.nz%2Finsights%2Fas-2550.10-ewp-major-inspection-update-what-fleet-operators-need-to-do><https://pinterest.com/pin/create/button/?url=https%3A%2F%2Fdeg.nz%2Finsights%2Fas-2550.10-ewp-major-inspection-update-what-fleet-operators-need-to-do>[mailto:https%3A%2F%2Fdeg.nz%2Finsights%2Fas-2550.10-ewp-major-inspection-update-what-fleet-operators-need-to-do](mailto:https%3A%2F%2Fdeg.nz%2Finsights%2Fas-2550.10-ewp-major-inspection-update-what-fleet-operators-need-to-do)

## Keep reading

### [![](https://deg.nz/hs-fs/hubfs/Image%20%282%29.jpeg?width=4032&height=3024&name=Image%20%282%29.jpeg) #wedothingstogether #wedoallthingssafely #wedothingsright EEA2026: Certainty, capability and some great conversations](https://deg.nz/insights/eea2026-certainty-capability-and-some-great-conversations)

### [![](https://deg.nz/hs-fs/hubfs/AI-Generated%20Media/Images/Professional%20Conference%20Room%20with%20Stapled%20Manual%20and%20Large%20Windows-1.png?width=1535&height=1025&name=Professional%20Conference%20Room%20with%20Stapled%20Manual%20and%20Large%20Windows-1.png) #wedothingsright #wedothingsbetter SM-EI consultation: what it means for network work](https://deg.nz/insights/sm-ei-consultation-what-it-means-for-network-work)

![DEG-primary logo-white-RGB-justified](https://deg.nz/hs-fs/hubfs/Website%20images/DEG-primary%20logo-white-RGB-justified.png?width=150&height=45&name=DEG-primary%20logo-white-RGB-justified.png "DEG-primary logo-white-RGB-justified")

 

EXPERTS IN CALIBRATION, CERTIFICATION  
& COMPLIANCE ENGINEERING

 

###### ©DEG 2025

###### [Privacy policy](https://deg.nz/hubfs/Privacy%20Policy.pdf)

###### [Terms & Conditions](https://deg.nz/hubfs/Terms%20and%20Conditions.pdf)

##### Hamilton +64 7 850 1177

##### Christchurch +64 3 348 6713

##### Timaru +64 3 688 6713

##### Dunedin +64 3 477 1713

<https://www.facebook.com/www.designengineering.co.nz><https://www.linkedin.com/company/design-engineering><https://www.instagram.com/deg_nz/>

```json
{
  "@context" : "https://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "DEG",
    "url" : "https://deg.nz/insights/author/deg"
  },
  "dateModified" : "2026-04-28T05:15:37.902Z",
  "datePublished" : "2026-04-28T05:15:37.000Z",
  "headline" : "AS 2550.10 EWP Major Inspection Update — What Fleet Operators Need to Do",
  "image" : [ "https://deg.nz/hubfs/ewp-photo2%20(1).jpg" ],
  "mainEntityOfPage" : {
    "@id" : "https://deg.nz/insights/as-2550.10-ewp-major-inspection-update-what-fleet-operators-need-to-do",
    "@type" : "WebPage"
  },
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "url" : "https://deg.nz/hubfs/Brand%20Logo.png"
    },
    "name" : "DEG"
  }
}
```